Αρχική Σελίδα ΠροϊόνταΑναλυτής θορύβου

National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation

Πιστοποίηση
Κίνα Shenzhen Jinxi Boyuan Technology Co., Ltd. Πιστοποιήσεις
Κίνα Shenzhen Jinxi Boyuan Technology Co., Ltd. Πιστοποιήσεις
Είμαι Online Chat Now

National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation

National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation
National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation

Μεγάλες Εικόνας :  National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation

Λεπτομέρειες:
Τόπος καταγωγής: ΚΙΝΑ
Μάρκα: National Instruments
Αριθμό μοντέλου: PXIE-4310
Πληρωμής & Αποστολής Όροι:
Ποσότητα παραγγελίας min: Ενας
Τιμή: $10,000/sets >=1 sets
Συσκευασία λεπτομέρειες: Τυποποιημένη συσκευασία
Delivery Time: Delivery time for minimum order quantity ≤ 30 days
Payment Terms: T/T ‌L/C
Δυνατότητα προσφοράς: 100 μονάδες/ημέρα
Επικοινωνία Συνομιλία τώρα

National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation

περιγραφή
Εγγύηση: 3 μήνες προσαρμοσμένη υποστήριξη: ΚΑΕ
Τόπος προέλευσης: Αμερικανός brand name: National Instruments
Αριθμός μοντέλου: PXIE-4310
Επισημαίνω:

8 analog input channels PXI Analog Input Module

,

400ks/s sampling rate Noise Analyzer

,

600 V channel isolation National Instruments PXIe-4310

OEM Support National Instruments PXIe-4310 PXI Analog Input Module
Customized for Your Requirements
The National Instruments PXIe-4310 PXI Analog Input Module (Part Number: 784813-01) is a high-performance solution featuring 8 analog input channels with simultaneous sampling capability. This advanced module delivers exceptional measurement precision and flexibility for industrial applications.
Key Features
  • 8 simultaneous sampling analog input channels
  • High sampling rate up to 400 kS/s per channel
  • Channel-to-channel isolation up to 600 V
  • Multiple input range configurations (-1V to 600V)
  • Programmable Butterworth filters (10 kHz, 100 kHz)
  • 16-bit resolution for precise measurements
  • Self-calibration function for improved accuracy
  • NI-DAQmx driver support for simplified configuration
National Instruments PXIe-4310 PXI Analog Input Module with 8 Channels 400ks/s Sampling Rate and 600 V Channel Isolation 0
Technical Specifications
Dimensions: 6.3 x 3.9 inches
Weight: 6.0 oz
Power Requirements: +3.3V (2.9W), +12V (7.1W)
Input Channels: 8 differential
Parameter Specification
Analog Input Voltage Ranges -1V to 1V, -10V to 10V, -120V to 120V, -2V to 2V, -300V to 300V, -5V to 5V, -60V to 60V, -600V to 600V
Maximum Isolation Voltage 600 V channel-to-channel
Filter Options Butterworth, 10 kHz and 100 kHz
Trigger/Clock Function Two PFI input lines
Compliance Meets industrial safety standards
Extended Capabilities
The PXIe-4310 module supports range expansion through terminal blocks. With TB-4310 (10V), the range extends to ±10V, and with TB-4310 (600V), it expands to ±600V. The module's self-calibration feature measures onboard reference voltages to maintain accuracy against environmental fluctuations.

Συνολική αξιολόγηση

5.0
Βασισμένο σε 50 αξιολογήσεις για αυτόν τον προμηθευτή

Εικόνα βαθμολόγησης

Ακολουθεί η κατανομή όλων των αξιολογήσεων
5 αστέρια
0%
4 αστέρια
0%
3 αστέρια
0%
2 αστέρια
0%
1 αστέρια
0%

Όλες οι κριτικές

K
Keysight N9020B MXA Signal Analyzer for Wireless Device Testing with Intuitive Multi-Touch Interface and United States Origin
Panama Oct 19.2025
La función de mapeo de cobertura Wi-Fi es una maravilla. Ahora optimizamos las redes de estos galpones enormes en horas, no en días. La eficiencia subió como la espuma.
K
Keysight N9020B MXA Signal Analyzer for Wireless Device Testing with Intuitive Multi-Touch Interface and United States Origin
Germany Oct 15.2025
Selbst bei 24/7-Dauerbetrieb bleibt die Drift minimal. Die Langzeitstabilität ist genau das, was wir für unsere Sendernetz-Überwachung brauchen.
K
Keysight N9020B MXA Signal Analyzer for Wireless Device Testing with Intuitive Multi-Touch Interface and United States Origin
Indonesia Aug 24.2025
Wah, buat cari sumber interferensi 4G/5G di lapangan, alat ini jago banget! Scan-nya cepat, hasilnya akurat. Gak perlu nebak-nebak lagi, langsung ketemu titik masalahnya.
Στοιχεία επικοινωνίας
Shenzhen Jinxi Boyuan Technology Co., Ltd.

Υπεύθυνος Επικοινωνίας: ALEXLEE

Τηλ.:: +86 15626514602

Στείλετε το ερώτημά σας απευθείας σε εμάς (0 / 3000)

Άλλα προϊόντα